EasyManua.ls Logo

Samsung AQV12A1ME - Page 14

Samsung AQV12A1ME
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Instructions and Installation
3-7
3-2-2(b) Refrigerant Adjustment
3-2-2(c) Flare unt fixing torque
Class For installation For service
Outter diameter
ø 6.35 (9000Btu, 12000Btu)
(Liquid Side)
ø 9.52 (9000Btu)
(Gas Side)
ø 12.7 (12000Btu)
(Gas Side)
160
300
500
200
350
550
Fixing Torque Final Torque
Torque (kg-cm)
Connection
Pipe Length
5m
(standard)
6~15m
Air-Purge
Method
Refer to the
detailed Air-Purge
Procedure
Refrigerant
Adjustment
Unnecessary
Add 20g of refrigerant
(R-22) for every 1m.
Air-Purge
Method
Purge air using a
vaccum pump
or an additional
refrigerant cylinder.
Refrigerant
Quantity
refer to
specification sheet
Add 20g of refrigerant
(R-22) for every 1m.
20 25 30 35 40 45
32.4
30.6
28.8
27.0
24.0
21.5
6.5
6
5.5
5
4.5
4
3.5
Outdoor inlet air DB temp.(˚C)
• MODEL NAME : AQV12A1ME (UQV12A1ME)
AQV12A2ME (UQV12A2ME)
S H 1 2 VA 1 ( S H 1 2 VA 1 X )
S H 1 2 VA 2 ( S H 1 2 VA 2 X )
20 25 30 35 40 45
32.4
30.6
28.8
27.0
24.0
21.5
7
6.5
6
5.5
5
4.5
4
Outdoor inlet air DB temp.(˚C)
• MODEL NAME : AQV09A1ME (UQV09A1ME)
AQV09A2ME (UQV09A2ME)
S H 0 9 VA 1 ( S H 0 9 VA 1 X )
S H 0 9 VA 2 ( S H 0 9 VA 2 X )
Samsung Electronics