EasyManua.ls Logo

Samsung AQV12A1ME - 5-4 Fault Diagnosis of Major Parts

Samsung AQV12A1ME
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-9
5-4 Fault Diagnosis of Major Parts
(Unit defect)
If the comp is locked.
-> Replace the comp.
If the comp is operating without the revolution of fan motor
-> Take out the protection cover.
-> Check the fan motor connector and replace the fan motor.
Troubleshooting
Parts
Indoor ”Temp.Sensor”
Indoor “Heat ex. Sensor”
Outdoor ”Temp.Sensor”
Outdoor “Deice Temp. Sensor”
Outdoor “Discharge
Temp.Sensor”
Outdoor “OLP Temp.Sensor”
Indoor Fan Motor
Outdoor Fan Motor
Stepping Motor
(UP/DOWN swing motor)
Diagnosis
Measure resistance with a tester.
Normal
Abnormal , O … open or short
Normal
Abnormal , O … open or short
Measure resistance between terminals (CN72) with a tester
Normal At ambient temperature (10°C ~ 30°C)
Abnormal
Measure the voltage between ground and signal wire of the fan motor
Normal
Abnormal Abnormal if voltage does not change from 0V to 5V.
Normal At ambient temperature (10°C ~ 30°C)
Abnormal , O … open or short
Measure resistance between red wire and each terminal.
Normal Approx. 380 at ambient temperature (20°C ~30°C)
Abnormal , O … open or short
Ambient temperature 15°C 20°C 25°C 30°C 35°C 40°C
Resistance of
14.68 12.09 10 8.31 6.94 5.83
thermistor[K]
Ambient temperature 0°C 10°C 20°C 30°C 40°C 50°C
Resistance of
553 362 242 166 165 82
thermistor[K]
between Resistance
Black, Red 275±10% Main
Black, White 350±10% Sub
between Voltage
Gray, Orange 05V~4.5V
Yellow, Orange 5V
between Voltage
Red, Blue 410±10% Main
Red, Yellow 325±10% Sub
Samsung Electronics