Refer to the service manual in the GSPN(see the rear cover) for the more information.
AIR CONDITIONER CONTENTS
SPLIT-TYPE AIR CONDITIONER
INDOOR UNIT OUTDOOR UNIT
Basic : AQV12NSAN
Model: AQV09UGAN
AQV12UGAN
Model Code : AQV09UGAN AQV09UGAX
AQV12UGAN AQV12UGAX
Q
good' sleep Mode
Q
Catechin Filter
Q
Silver Nano Evaporator
Q
Deodorizing Filter
Q
Anti-Bacterial Cross Fan

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Samsung AQV12UGAN and is the answer not in the manual?

Samsung AQV12UGAN Specifications

General IconGeneral
TypeSplit system
Hose length (max)15 m
Remotely operatedYes
Refrigerating mediumR410A
Cooling capacity (max)11260 BTU/h
Dehumidifying capacity1.4 l/h
Heating capacity (max)13649 BTU/h
Air conditioner functionscooling, heating
Cooling capacity in watts (max)3300 W
Heating capacity in watts (max)4000 W
Cooling energy efficiency (EER, W/W)3.21
Heating energy efficiency (COP, W/W)3.61
Indoor unit typeWall-mountable
Indoor unit weight10000 g
Indoor unit dimensions (WxDxH)820 x 190 x 285 mm
Indoor unit noise level (high speed)36 dB
Outdoor unit weight33000 g
Outdoor unit noise level47 dB
Outdoor unit dimensions (WxDxH)720 x 265 x 548 mm
Airflow9 m³/h
Annual energy consumption514 kWh
Power consumption (cooling) (max)1028 W
Power consumption (heating) (max)1108 W

Summary

Precautions

Precautions for the Service

Guidelines for safe and correct service procedures, including part replacement and assembly.

Precautions for Static Electricity and PL

Safety measures against static discharge and physical hazards during repair.

Precautions for the Safety

General safety instructions to prevent electric shock, fire, and damage from electrical components.

Disassembly and Reassembly

Indoor Unit Disassembly

Step-by-step guide for safely disassembling the indoor unit components.

Outdoor Unit Disassembly

Step-by-step guide for safely disassembling the outdoor unit components.

Troubleshooting

Setting Option Setup Method

Procedure for configuring unit options using the remote control.

Display Error and Check Method

Explains error codes displayed by the unit and their diagnostic methods.

Communication Error

Troubleshooting steps for communication errors between indoor and outdoor units.

Indoor Temperature Sensor Error

Steps to diagnose and resolve indoor temperature sensor faults.

Indoor Heat Exchanger Sensor Error

Steps to diagnose and resolve indoor heat exchanger sensor faults.

Indoor Fan Motor Speed Error

Troubleshooting for errors related to indoor fan motor speed detection.

MPI Error

Diagnostic steps for MPI (Micro Plasma Ion) errors.

Outdoor Temperature Sensor Error

Steps to diagnose and resolve outdoor temperature sensor faults.

Coil Temperature Sensor Error

Steps to diagnose and resolve coil temperature sensor faults.

Discharge Temperature Sensor Error

Steps to diagnose and resolve discharge temperature sensor faults.

No Power (Initial Diagnosis)

Procedure for diagnosing and resolving a completely dead unit or no power issue.