EasyManua.ls Logo

Samsung AR18CSFCMWKN - Refrigerating Cycle Diagram

Samsung AR18CSFCMWKN
141 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...

7-10 Samsung Electronics
SAMSUNG PROPRIETARY. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION
SAMSUNG PROPRIETARY. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION
Electronic Expansion
Valve - Main 2
(E_M2)
Thermistor - In 1
(T_I1)
ROOM A
ROOM A
Outdoor Heat Exchanger (OHX)
Outdoor Fan Motor (OFM)
Thermistor - Discharge pipe
(T_D)
Thermistor - In 2
(T_I2)
Thermistor - Out 1
(T_O1)
Thermistor - Out 2
(T_O2)
Electronic Expansion
Valve - Main 1
(E_M1)
Service Valve
- Liquid Pipe1 (SV_L1)
ROOM B
Service Valve
- Liquid Pipe2 (SV_L2)
Service Valve
- Gas Pipe1 (SV_G1)
ROOM B
Service Valve
- Gas Pipe2 (SV_G2)
ROOM C
Electronic Expansion
Valve - Main 3
(E_M3)
Service Valve
- Liquid Pipe3 (SV_L3)
Filter
Thermistor - In 3
(T_I3)
ROOM C
Service Valve
- Gas Pipe3 (SV_G3)
Thermistor - Out 3
(T_O3)
Compressor (Comp)
Thermistor
Cond Out (T_CO)
Accmulator (AC)
Temperature High Pressure Gas High
Temperature Mid Pressure Liquid Mid
Temperature Low Pressure Liquid Low
Temperature Low Pressure Gas Low
Filter
Filter
7-8 Refrigerating Cycle Diagram
Temperature High Pressure Gas High
Temperature Mid Pressure Liquid Mid
Temperature Low Pressure Liquid Low
Temperature Low Pressure Gas Low
Electronic Expansion
Valve - Main 2
(E_M2)
Thermistor - In 1
(T_I1)
ROOM A
ROOM A
Outdoor Heat Exchanger (OHX)
Outdoor Fan Motor (OFM)
Thermistor - Discharge pipe
(T_D)
Thermistor - Out 1
(T_O1)
Electronic Expansion
Valve - Main 1
(E_M1)
Service Valve
- Liquid Pipe1 (SV_L1)
Service Valve
- Gas Pipe1 (SV_G1)
ROOM B
Service Valve
- Liquid Pipe2 (SV_L2)
Filter
Thermistor - In 2
(T_I2)
Compressor (Comp)
Thermistor
Cond Out (T_CO)
ROOM B
Service Valve
- Gas Pipe4 (SV_G2)
Thermistor - Out 2
(T_O2)
Accmulator (AC)
Filter
■ AJ020BXJ2CH
■ AJ024BXJ3CH

Table of Contents