EasyManua.ls Logo

Samsung AR18CSFCMWKN - Page 20

Samsung AR18CSFCMWKN
141 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Product Specifications
2-14 Samsung Electronics
SAMSUNG PROPRIETARY. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION
SAMSUNG PROPRIETARY. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION
SAMSUNG PROPRIETARY. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION
SAMSUNG PROPRIETARY. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION
Design Model Name Model
AJ020BXJ2CH AJ024BXJ3CH AJ036BXJ4CH AJ048BXJ5CH AJ020CXS3CH AJ024CXS4CH AJ030CXS4CH AJ036CXS4CH
Model
Capacity
[kBtu/h]
20 24 36 48 20 24 30 36
AJ009/012BNHDCH 9/12
AJ015BNHDCH 15
AJ018BNHDCH 18
AC009/012BNJDCH 9/12
AC015BNJDCH 15
AC018BNJDCH 18
AC012BNZDCH 12
AC018BNZDCH 18
AC024BNZDCH 24
Combination guide when applying AJ0**BNHDCH/AA (Duct S) or AC0**BNZDCH/AA (MPAH) indoor units.
- Only one AC***BNZDCH/AA (MPAH) indoor unit can be included in the combination.
- Only one AJ***BNHDCH/AA (Duct S) indoor unit can be included in the combination.
- AJ***BNHDCH/AA (Duct S) indoor units cannot be connected to outdoor unit model AJ020BXJ2CH/AA.
- If AJ0**BNHDCH/AA (Duct S) or AC0**BNZDCH/AA (MPAH) indoor units are included in the combination, the total sum of
indoor unit nominal capacity cannot exceed the outdoor unit nominal capacity (max. 100% design diversity/capacity ratio).
- If the indoor unit combination includes AJ0**BNHDCH/AA (Duct S) or AC0**BNZDCH/AA (MPAH) indoor units and does not
meet the installation combination restrictions, error code E563 error will display and the system will not operate.
- If error code E563 occurs, Cool Mode and Pipe Check operations are still possible.
Combination Guide for Systems That Include AJ***BNHDCH/AA or AC***BNZDCH/AA
Outdoor Unit Model(US code)
Mixed
Installation
4 Indoor Unit
Connection
3 Indoor Unit
Connection
2 Indoor Unit
Connection
Combination
Ratio
Outdoor
Index
JXH24J3B (AJ024BXJ3CH/AA) Not Allowed Not Allowed Not Allowed Allowed 1.0 24
JXH36J4B (AJ036BXJ4CH/AA) Not Allowed Not Allowed Allowed Allowed 1.0 36
JXH48J5B (AJ048BXJ5CH/AA) Not Allowed Allowed Allowed Allowed 1.0 48
JXH20S3C (AJ020CXS3CH/AA) Not Allowed Not Allowed Not Allowed Allowed 1.0 21
JXH24S4C (AJ024CXS4CH/AA) Not Allowed Not Allowed Allowed Allowed 1.0 24
JXH30S4C (AJ030CXS4CH/AA) Not Allowed Not Allowed Allowed Allowed 1.0 30
JXH36S4C (AJ036CXS4CH/AA) Not Allowed Not Allowed Allowed Allowed 1.0 36
Mixed installation means mixing AJ***BNHDCH/AA and AC***BNZDCH/AA units on the same system.
CAUTION