Product Specifications
Samsung Electronics 2-13
Design Model Name Model
AJ020BXJ2CH AJ024BXJ3CH AJ036BXJ4CH AJ048BXJ5CH AJ020BXS3CH AJ024BXS4CH AJ030BXS4CH AJ036BXS4CH
Model
Capacity
[kBtu/h]
20 24 36 48 20 24 30 36
AC009/012BNJDCH 9/12
AC015BNJDCH 15
AC018BNJDCH 18
AC012BNZDCH 12
AC018BNZDCH 18
AC024BNZDCH 24
Combination Guide for Installation including AJ***BNHDCH / AJ***BNZDCH
- Only one AJ***BNZDCH (MPAH)indoor unit can be included in the combination.
- AJ***BNHDCH (Duct S) indoor units cannot be connected to outdoor unit model AJ020BXJ2CH.
- If AJ***BNHDCH and AC***BNZDCH indoor units are included in the combination, total sum of indoor unit index must be configured so as not to exceed the outdoor index.
- Ifthe indoor unit combination includes AJ***BNHDCH /AC***BNZDCH indoor units and does not meet the installation combination restrictions, E563 error will display andthe system will not operate.
. If error code E563 occurs, Cool Mode Try run and Pipe Check operations are still possible.
Combination Guide for Installation including AJ***BNHDCH / AC***BNZDCH
Outdoor Unit
Mixed
Installation
4rooms
Installation
3rooms
Installation
2rooms
Installation
Combination
Ratio
Outdoor
Index
AJ024BXJ3CH Enabled N/A N/A Enabled 1.0 24
AJ036BXJ4CH Enabled N/A N/A Enabled 1.0 36
AJ048BXJ5CH Enabled N/A Enabled Enabled 1.0 48
AJ020BXS3CH Enabled N/A N/A Enabled 1.0 21
AJ024BXS4CH Enabled N/A N/A Enabled 1.0 24
AJ030BXS4CH Enabled N/A N/A Enabled 1.0 30
AJ036BXS4CH Enabled N/A N/A Enabled 1.0 36
Mixed installation means the case of mixing AJ***BNHDCH and AC***BNZDCH.