3-2 Samsung Electronics
3-2 Controls and Components
3-2-1 Thermostat
OFF :
When room temperature is lowered by the air
conditioner, the gas within the thermostat will
contract and cause a break in the electrical
contact. The compressor will then stop.
After the compressor stops, the room
temperature will rise.
ON :
As the room temperature increases to a
selected level, the gas within the thermostat
expands causing electrical contact, which
provides the source of electric power to the
compressor. The room temperature will fall
and the cycle will repeat.
Control Operation :
By turning the control knob clockwise (toward
higher numbers), the temperature will be cooler.
By turning the control knob counterclockwise
(toward lower numbers), the temperature will be
warmer.
Level 1 : Cool air will be supplied above 30~35¡C
Cool air will cease below 28~32.5¡C
Level 12 : Cool air will be supplied above 17.4~20.4¡C
Cool air will cease below 14.4~17.4¡C
OFF
LOW
COOL
LOW
FAN
HI
FAN
HI
COOL
4
2
8
COOLEST
12
10
6
OPERATION
THERMOSTAT
OFF
LOW
COOL
LOW
FAN
HI
FAN
HI
COOL
4
2
8
COOLEST
12
10
6
OPERATION
THERMOSTAT
Operating mode
selection dial
<AW07A0SE/AW09A0SE>
<AW07A1SE/AW09A1SE>
Temperature
control dial
Operating mode
selection dial
Temperature
control dial
Air flow blade swing switch
AW07A1SE/AW09A1SE-1 3/12/99 5:27 PM Page 3-2