Alignment & Troubleshooting
Service Manual
4-12
Samsung Electronics
Depth1 Depth2 Meaning
105-MHV Bias
0000-Y MHV Bias Yellow MHV bias voltage on at normal drive level
0010-M MHV Bias Magenta, Cyan MHV bias voltage on at normal drive level
0030-K MHV Bias Black MHV bias voltage on at normal drive level
0100-M MHV AC Magenta, Cyan MHV AC bias voltage on at normal drive level
0120-K MHV AC Black MHV AC bias voltage on at normal drive level
106-Dev Bias
0000-Y Dev Bias Yellow Dev bias voltage on at normal drive level
0010-M Dev Bias Magenta Dev bias voltage on at normal drive level
0020-C Dev Bias Cyan Dev bias voltage on at normal drive level
0030-K Dev Bias Black Dev bias voltage on at normal drive level
0031-K Dev AC Black Dev bias AC voltage on at normal drive level
0032-C Dev AC Cyan Dev bias AC voltage on at normal drive level
0033-M Dev AC Magenta Dev bias AC voltage on at normal drive level
0034-Y Dev AC Yelllow Dev bias AC voltage on at normal drive level
107-Transfer Bias
0000-Y THV Bias Yellow THV bias voltage on at normal drive level
0010-M THV Bias Magenta THV bias voltage on at normal drive level
0020-C THV Bias Cyan THV bias voltage on at normal drive level
0030-K THV Bias Black THV bias voltage on at normal drive level
0040-Y THV Bias R Detect what the THV value is on the THV Roller
0120-ATTR+ Bias ATTR plus bias voltage on at normal drive level
0140-ATTR- Bias ATTR Minus bias voltage on at normal drive level
0160-Erase Lamp Make a OPC surface voltage equal
109-Fuser Heater
0000-Temp A Detects what the temperature center is on fuser.
0010-Temp B Detects what the temperature side is on fuser.
0030-Fuser Mot Fwd Fuser Motor Forward On/Off
0031-Fuser Mot Bwd Fuser Motor Backward On/Off
0040-Fuser Fan Run Fuser Fan Motor On/Off
0050-Fuser Bias Fuser bias voltage on at normal drive level
0090-Fuser Power On It controls temperature of fuser as 180 degrees.
0110-Fuser Fuse 1 R Detect if the life of fuser1 is exhausted.
110-LSU
0000-LSU Motor 1 Rdy Detects if LSU motor1 runs at normal speed.
0010-LSU Motor 2 Rdy Detects if LSU motor2 runs at normal speed.
0060-LSU Motor 1 Run LSU Motor1 On/Off
0070-LSU Motor 2 Run LSU Motor2 On/Off
0080-LD Power 1 LSU LD1 enable On/Off (yellow)
0090-LD Power 2 LSU LD2 enable On/Off (magenta)
0100-LD Power 3 LSU LD3 enable On/Off (cyan)
0110-LD Power 4 LSU LD4 enable On/Off (black)
112-ACR 0010-Manu Regi Clear Clear Manual Offset Value of Color Regi.