4-10 Replacement of Air Filter
1. Pull out the spacer pins at both ends of the Air
Filter. Then the locking clamps inside are released.
2. Lift the Air Filter off the post carefully.
Note
: Spacer pins are not detachable from the Air Filter.
4-11 Replacement of High Voltage Capacitor
NOTE : It is not necessary to remove Magnetron in
order to remove HVC.
1. Remove the outer panel and back cover.
2. Discharge the high voltage capacitor.
3. Remove HVT wire and H.V.Fuse.
4. Remove screws securing HVC bracket.