1. ERROR CODE NUMBERING RULE is applied to a microwave oven and an oven.(CMO, OTR, Grill, Convection,
Commercial etc.)
2. All sensors and devices have their own number. ex) Gas Sensor = 1, Temp. Sensor = 2, ...
3. Of each device, No.1 and No.2 refer to “Open Error” (not sensed) and “Short Error”, respectively.
4. This numbering rule has been applied to models to have been developed since January, 1, 2005. (But, GE or
Customize model are excluded.)
DEVICE ERROR CASE
0- Others 1- Open
1- Gas Sensor 2- Short
2- Temp. Sensor
3- Weight Sensor
4- Easy/PH Sensor
5- EEPROM
Gas Sensor
Error
Code
Case
Solution
Page
E-11
GAS SENSOR OPEN
In case the value of the gas
sensor value is more than 210
during operation/cancellation.
Check sensor part connection of sensor
housing and PCB’s connector.
26 Page
E-12
GAS SENSOR SHORT
In case the value of the gas
sensor value is less than 6 during
operation/cancellation.
27 Page
E-13
GAS SENSOR MAX TIME
In case of gas sensor time is over
estimated cook time.
28 Page