The following table indicates the temperature and humidity ranges, within which the air conditioner
can be used.
Temperature and Humidity Ranges
Gaudi_IB_DB98-28944A_E_12.14.07.indd 12 2008-1-25 16:55:47
E-
12
MODE OPERATING CONDITIONS IF OUT OF CONDITIONS
COOLING
Indoor temp: 1
8˚C~32˚C
-
A safety device will stop continuously
the system functioning;
-
Condensation may occur on the indoor
unit with risk to have either water blow
off or drops on the floor;
Indoor humidity: below 80%
Outdoor temp: -15˚C~4
3˚C
HEATING
Indoor temp: below 27˚C
-
A safety device will stop continuously
the system functioning;
Outdoor temp: -20˚C~24˚C
DEHUMIDIFYING
Indoor temp: 18˚C~32˚C
-
A safety device will stop continuously
the system functioning;
-
Condensation may occur on the indoor
unit with risk to have either water blow
off or drops on the floor;
Outdoor temp: -1
5˚C~43˚C
POWER SUPP
LY
Single phase rated voltage
minimum and maximum limit
220-240V~, 50Hz
198V - 264V
• Any damage occurs out of condition specified cannot be covered by product warranty. If the system
works continuously outside of conditions, its performance and
reliability will be compromised.
• If the outdoor temperature is as low as 0°C, the heating capacity may drop depending on the
operating condition.