11-4Samsung Electronics
11-2 Additional Function
Compensation for lost temperature in heating operation
• Reduces the difference between an actual room temperature and a sensed
temperature by the air conditioner when heating.
Adjusting filter cleaning cycle
• You can adjust the cycle for filter sign indicator.
Hot water heater
You must adjust the K7 when you install the hot water heater.
External Control
• You must adjust the K11 when you use external control.
SW06
K5 K6 K7 K8
SW06
K5 K6 K7 K8
Switch No. Switch ON Switch OFF
K5
2˚C compensation 5˚C compensation
Switch No. Switch ON Switch OFF
K6
1,000 hours 2,000 hours
Switch No. Switch ON Switch OFF
K7
No use of hot water heater Use of hot water heater
SW06
K5 K6 K7 K8
SW07
K 1
K 2
K 3
K 4
Switch No. Switch ON Switch OFF
K11
No use of external control Use of external control