Ⅲ.ADJUSTMENT
4) B/T LEVEL ADJ
After changing the MAIN PCB, adjust the Standard Voltage LEVEL.
<How to adjust>
a...Prepare the POWER SUPPLY.
b...Connect the camera to the POWER SUPPLY.
c...Set the voltage to 2.71V.
d...Download the adjustment file and save it to SD memory card.
e...Insert the SD memory card that has the program file and turn on the camera.
f...Adjustment will be done automatically. (There are no information on the LCD)
g...After completed the adjustment, the camera is turned off automatically.
<Description of TXT file>
When modify the program, use the Memo Pad of Windows and save it as "th73f_adj.txt".
Use only section related to each adjustment.
//----------adjustmnet----------//
starttotal
setreset
//adj_controlprogress_sig_start
//----------OB----------//
adj_controlcheck_process_id65535//
adj_controlprogress_sig_on
adj_controlsave_log_file