The designs of the unit and the connection valve are subject to change according to the model.
Piping length and the height.
A-unit
B-unit
Pipe size
Unit
Liquid
1/4
"
1/4
"
GAS
3/8
"
3/8
"
MAX.
piping length
A
15 m
15 m
MAX.
height
B
7 m
7 m
A
B
INDOOR UNIT
OUTDOOR UNIT
A
B
160 mm
or more
20 mm
or more
Respect the clearances and maximum lengths indicated in the diagram below when installing the unit.
100 mm
or more
300 mm
minimum
600 mm
minimum
600 mm
minimum
300 mm
minimum
A-unit
7,000(2.05kW) or
9,000 Btu/h(2.63kW)
B-unit
9,000(2.63kW) or
12,000Btu/h(3.51kW)
Circuit breaker
(20A)
Main power switch
B
(7 metres maximum)
A
(15 metres
maximum)
18,000Btu/h
A-unit
B-unit
Pipe size
Unit
Liquid
1/4
"
1/4
"
GAS
3/8
"
3/8
"
MAX.
piping length
A
15 m
15 m
MAX.
height
B
7 m
7 m
19,000Btu/h
E-5
ENGLISH
PREPARING THE INSTALLATION
18,000Btu/h
Indoor unit Outdoor unit
Power supply
Ø, V, Hz
MH18AP1(P2)-09
MH18AP1(P2)X
1,220-240~,50
19,000Btu/h
Indoor unit Outdoor unit
MH19AP1(P2)-07
MH19AP1(P2)-12
MH19AP1(P2)X
1,220-240~,50
Power supply
Ø, V, Hz