E-6
Deciding on Where to Install the Air Conditioner (cont.)
PREPARING THE INSTALLATION
Piping length and the height.
A
B
INDOOR UNIT
OUTDOOR UNIT
A
B
160 mm
or more
20 mm
or more
Respect the clearances and maximum lengths indicated in the diagram below when installing the unit.
100 mm
or more
300 mm
minimum
600 mm
minimum
600 mm
minimum
300 mm
minimum
A-unit
12,000 Btu/h(3.51kW)
B-unit
12,000 Btu/h(3.51kW)
Circuit breaker
(20A)
Main power switch
B
(7 metres maximum)
A
(15 metres
maximum)
A-unit
B-unit
Pipe size
Unit
Liquid
1/4
"
1/4
"
GAS
3/8
"
3/8
"
MAX.
piping length
A
15 m
15 m
MAX.
height
B
7 m
7 m
The designs of the unit and the connection valve are subject to change according to the model.
24,000Btu/h
Indoor unit Outdoor unit
Power supply
Ø, V, Hz
MH24AP1(P2)-12
MH24AP1(P2)X
1,220-240~,50