This MMC is used to adjust individual timers as necessary. All available timers are
described in the TABLE OF TIMERS AND VALUES.
NOTE: Seconds are shown as 'SEC', milliseconds as 'MS', and minutes as 'MIN'.
PROCEDURE LCD DISPLAY
1. Press [TRANSFER] and dial 50
2. Press [VOLUME (-) or (+)] to select a timer
(e.g. ALM R DUR)
3. Enter new value using KEYPAD
4. Press [TRANSFER] to save and exit
DEFAULT DATA
See TABLE OF TIMERS AND VALUES
RELATED MMC
NONE
TABLE OF TIMERS AND VALUES
DISPLAY DESCRIPTION DEFAULT RANGE
ALM R INT controls the time length between ring attempts 025SEC 250SEC
(Alarm ring at a station when alarm reminder is set.
interval)
ALM R DUR controls the length of ring cycle duration when 010SEC 1~250SEC
(Alarm ring alarm reminder is set at a station.
duration)
ARDL INT controls the time between attempts after Auto 045SEC 1~250SEC
(Auto Redial Redial is set 'ON' at a station.
interval)
ARDL RELS controls the duration of a Ring No Answer 045SEC 1~250SEC
(Auto Redial condition on an auto-redial number dialed
release time) before auto redial is canceled.
CBACK NOA controls the time before the callback is canceled 030SEC 1~250SEC
(Callback no when a callback detects Ring No Answer
answer time)
CO CO DIS monitors the duration of an unsupervised 010MIN 1~250MIN
(CO to CO conference, external call forward, or DISA call.
disconnect upon expiring, both trunks are disconnected.
time)
DISA F DG controls how long the system will wait for 025SEC 1~250SEC
dialing to begin the DISA incoming call.
DISA I DG controls the grace period between dialing valid 025SEC 1~250SEC
digits before dropping the call to DISA user.
DISA RING controls no answer time for DISA internal calling. 030SEC 1~250SEC
DOOR RELS controls the duration of time before the door 1500MS 100~
(Door release lock relay deactivates. 2500MS
time)
NX-SERIES HYBRID KEY SYSTEM PROGRAMMING SECTION
MMC 50 SYSTEM TIMERS
4Programming 1999.9.15 12:43 PM 페이지48