21
Clearance for built-in installation
Installing the outdoor unit only
When installing built-in to the wall, maintain the clearance from the back, top, bottom, and sides of the product in order to secure air flow.
Clearance for OH46F/OH55A/OH55F ( ): 50 mm or more
Clearance for OH75A/OH75F/OH85F ( )
Example 1) Exposure to direct sunlight: 200 mm or more
Example 2) Atmospheric temperatures under 35 ℃ without direct sunlight: 60 mm or more
"
If the unit is subjected to excess heat due to an insufficient gap, this may cause a malfunction, which will not be covered by the warranty.
OH46F/OH55A/OH55F
Partition
Partition
Wall or
obstacle
Side view
OH75A/OH75F/OH85F
Wall or
obstacle
Partition
Side view