Samsung OSLO R70 Series - CPU Fan Control

Samsung OSLO R70 Series
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4- 18
4.
Troubleshooting
6) CPU Fan Control
1) Fan Operation Analysis
- One can turn the fan on & off and check the fan's operational conditions without
system disassembly
Figure (1) Fan off Figure (2) Fan on
- SAFC's default setting is "Fan off" or "Minimum Fan Speed".
- Press "ON" in "ON/OFF Control" Fan is turned on to maximum fan speed.
- Press "OFF" in "ON/OFF Control" Fan returns to default setting.
2) Fan RPM Pass level.
No Item Mode
rpm Design guideline
SPEC : ± 10%
1FANVoltage
Off
0
IDLE
1800 rpm
LOW
2200 rpm
MID
2600 rpm
HIGH
3000 rpm
1단계
2단계
3단계
4단계
Figure (3) Fan Step Control
> Fan Voltage Measurement
- Read Fan RPM indicated in SAFC.
> Fan Voltage Pass/Fail determination
- If Fan RPM satisfies "rpm spec +/-10%", then Fan test is "PASS" .
- This Document can not be used without Samsung's authorization -
Fan rpm : 1800 rpm
SAFC will be upgraded to
include Fan RPM
1st step
2nd step
3rd step
4th step