4.Troubleshooting
•MethodofColorCalibration(A V)
1)ApplytheNTSC/PALLattice(N0.3)patternsignaltotheA VIN1port.
2)PresstheSourcekeytoswitchto“A V1”mode.
3)EnterServicemode.
4)Selectthe“ADC”menu.
5)Selectthe“A VCalibration”menu.
6)In“A VCalibrationOff”status,pressthe“
”keytoperformCalibration.
7)WhenCalibrationiscomplete,itreturnstothehigh-levelmenu.
8)Youcanseethechangeofthe“A VCalibration”statusfromFailuretoSuccess.
•MethodofColorCalibration(Component)
1)Applythe720pLattice(N0.6)patternsignaltotheComponentIN1port.
2)PresstheSourcekeytoswitchto“Component1”mode.
3)EnterServicemode.
4)Selectthe“ADC”menu.
5)Selectthe“CompCalibration”menu.
6)In“CompCalibrationOff”status,pressthe“
”keytoperformCalibration.
7)WhenCalibrationiscomplete,itreturnstothehigh-levelmenu.
8)Youcanseethechangeofthe“CompCalibration”statusfromFailuretoSuccess.
•MethodofColorCalibration(PC)
1)ApplytheVESAXGALattice(N0.21)patternsignaltothePCINport.
2)PresstheSourcekeytoswitchto“PC”mode.
3)EnterServicemode.
4)Selectthe“ADC”menu.
5)Selectthe“PCCalibration”menu.
6)In“PCCalibrationOff”status,pressthe“
”keytoperformCalibration.
7)WhenCalibrationiscomplete,itreturnstothehigh-levelmenu.
8)Youcanseethechangeofthe“PCCalibration”statusfromFailuretoSuccess.