EasyManua.ls Logo

Samsung RB1955VQ - C-Fan Motor Delay Function

Samsung RB1955VQ
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
25
Operation Function
1
2
3
4
5
6
7
8
9
10
11
No
Include R-fan activation
Defrost heater activation
Initial power is activated ON
Outer temperature is over 95
Outer temperature is below 68
Exhibition mode is operated together
Led ON when COMP activation is included
Led ON F-fan activation is included
Led ON when F-heater activation is included
Led ON when F-lamp activation is included
Led ON when R-lamp activation is included
Operation Remark
R-fan
R-defrost heater
Initial start mode
Over load mode
Low temp.mode
Exhibition mode
Comp
F-fan
F-defrost heater
F-Lamp
R-Lamp
Ref. 6.button scan
and display circuitry
FREEZER:10digit
FREEZER: 1digit
REFRIGERATOR:10digit
REFRIGERATOR: 1digit
Content
a : REFRIGERATOR 1 digit
c : REFRIGERATOR 1 digit
d : REFRIGERATOR 1 digit
e : REFRIGERATOR 1 digit
f : REFRIGERATOR 1 digit
g : REFRIGERATOR 1 digit
a : FREEZER 1 digit
b : FREEZER 1 digit
d : FREEZER 1 digit
a : FREEZER 10 digit
b : FREEZER 10 digit
Display LED
Table 2. Display table of the presently operating parts.
l According to the ambient temperature, the condenser fan located in the machine compartment is
operated with different modes.
3, 4, and 5 only explains the system operation states according to the ambient condition.
9-11) C-Fan Motor Delay Function of the Machine Compartment
Ranges of ambient temp.
Above 66
61 ~ 65
Below 60
C-FAN is ON as soon as the compressor is on.
C-FAN is ON with 5 minutes delay from the compressor on.
C-FAN is OFF regardless of the compressor operation.
C-FAN
Delay function
Operation

Related product manuals