# tsRB195AB RevB 03/30/2011 1
Fast Track Troubleshooting
IMPORTANT SAFETY NOTICE ―For Technicians Only This service data sheet is
intended for use by persons having electrical, electronic, and mechanical experience
and knowledge at a level generally considered acceptable in the appliance repair trade.
Any attempt to repair a major appliance may result in personal injury and property
damage. The manufacturer or seller cannot be responsible, nor assume any liability for
injury or damage of any kind arising from the use of this data sheet.
Models
RB195AB**/XAA
RB197AB**/XAA
RB215AB**/XAA
RB217AB**/XAA
Press Freezer button a
third time to Force Defrost
for Fridge & Freezer,
measure defrost voltages
at main PCB
Wait 5 seconds
between button
pushes
Press the Freezer button
a second time to Force
Fridge Defrost. Measure
defrost voltage at main
PCB.
Press the Freezer button
one time at the Test Mode
to Force Compressor Run.
Measure fan and compres-
sor voltage at main PCB.
Self Diagnosis: Press the Pwr FreezePwr
Cool buttons simultaneously for 8-12 seconds
(No sound when both buttons are pressed at
the same time) until the display quits blinking.
Release the buttons and read Fault Codes.
This will also cancel the Fault Mode created by
self-diagnosis at power up.
Forced Mode: Press the Pwr
Freeze Fridge buttons simultane-
ously for 8-12 seconds (No sound
when both buttons are pressed at
the same time) until the display
beeps and goes blank.
Publication # tsRB195AB Revision Date 03/30/2011
Sealed System
Component Value Chart
Component Resistance Wattage Voltage
Fridge Defrost Heater 120Ω 120 120vac
Freezer Defrost Heater 60Ω 240 120vac
Fill Tube 1108Ω 13 120vac
Sensors 2.5kΩ-89k N/A 1~4.5vdc
Fans N/A N/A 7~12vdc
Sales Mode, No Compressor Operation
Press Power Freeze & Freezer temp buttons
simultaneously for 3 sec ( you will hear a ―Ding
Dong‖) to remove or put into Sales Mode. When
in the Sales Mode the Display will show "OF" "OF"
Removing power will not cancel this mode.
Refrigerant Charge
R134a 5.64 oz.
SUPPORT INFORMATION
Training Plus One http://my.plus1solutions.net/clientPortals/samsung/
Help GSPN http://service.samsungportal.com/
Samsung Product Support TV http://support-us.samsung.com/spstv/howto.jsp
Customer information videos and chat programs. Programs for Fridges, Laundry, Ranges & D/W
Notice: Bulletin
top hinge change
Question and Answer IconNeed help?

Do you have a question about the Samsung rb195ab** xaa and is the answer not in the manual?

Samsung rb195ab** xaa Specifications

General IconGeneral
BrandSamsung
Modelrb195ab** xaa
CategoryRefrigerator
LanguageEnglish

Summary

Fast Track Troubleshooting

IMPORTANT SAFETY NOTICE

Safety notice for technicians regarding potential injury and property damage during appliance repair.

Self Diagnosis

Instructions for entering self-diagnosis mode and reading fault codes.

Forced Mode

Procedure to enter forced mode for testing by pressing specific buttons.

DC FAN MOTORS

DC FAN MOTORS

Explanation of DC fan motor operation, speeds, and fault detection by the Main PCB.

Sensors and Fan Operation

Sensors

Description of sensor functions for defrost, compartment temp, and ice production.

How to Check Sensor Resistances Accurately

Step-by-step guide to accurately check sensor resistances using an ice slurry method.

Defrost and Diagnostic Code Information

Samsung 'Refrigerator' Diagnostic Code Quick Guide

Guide to diagnostic error codes, trouble description, and testing procedures.

I/M-SENSOR Error

Troubleshooting for Ice Maker Sensor errors: open/short circuit, connector failure.

R-SENSOR Error

Troubleshooting for Refrigerator Room Sensor errors: open/short circuit, connector failure.

R-DEFROSTING ERROR

Troubleshooting for Refrigerator Defrosting Heater errors: open/short circuit, fuse/bi-metal failure.

F-FAN ERROR

Troubleshooting for Freezer Evaporator Fan errors: fan not spinning or feedback line open.

Main PCB Layout and Components