26
Operation Function
3) Door open
when door is open, the related display shows an actual temperature.
3-1) Display range of freezer is -35
˚C
~ 30
˚C
and refrigerator is -9
˚C
~9
˚C
.
3-2) If freezer inner temperature is above 0
˚C
for 10 minute, the display of the selected temp.
will blink.
3-3) If refrigerator inner temperature is above 15
˚C
for 10 minute, the display of the selected
temp. will blink.
3-4) When door is open, 1
˚C
will increase after delay time from the display before door opens.
When door close, 1
˚C
will decrease after delay time if there is a change in inner
temperature. Temperature will reach up to presently selected notch.
4) Defrost Display function
4-1) If defrost starts both freezer and refrigerator display the selected temperature. So it will
not blink for 2 hours even if it sensed faulty in inner temperature, after 2 hours it will
decide to blink or not.
❈ code for temperature might change due to after the progress in development in products
NO
1
2
3
4
5
6
7
8
DA41-00128C
DA41-00127B
DA26-30111J
DA32-00006C
DA32-00006C
DA32-10105T
DA32-10105S
DA32-10105W
PBA MAIN
PBAPANEL
DC TRANS
F, R DEF SENSOR
F, R DEF SENSOR
R SENSOR
F SENSOR
EXT SENSOR
W2 PJT CANADA
W2 PJT CANADA
105V/50,60Hz
PX-41C
PX-41C
PX-41C
PX-41C
PX-41C
1
1
1
1
1
1
1
1
SPEC Q’ty RemarkCODE NO ITEM
(PCB Part List)
State of COMP cooling fan according to the ambient temperature (When COMP. is re-started)
- always OFF COMP cooling fan when ambient temperature is below 5
˚C
.
- COMP cooling fan always switch ON after 9 minute when ambient temperature is 6
˚C
~10
˚C
.
- COMP cooling fan always switch ON after 6 minute when ambient temperature is 11
˚C
~15
˚C
.
- COMP cooling fan always switch ON after 3 minute when ambient temperature is 16
˚C
~21
˚C
.
- COMP cooling fan always switch ON when ambient temperature is over 21
˚C
.
Reference