1) When the freezer temperature is lower than 50, all functions on the display panel will be restored.
2) When the freezer temperature is higher than 50, all functions will be initialized.
(2 for the freezer, 38 for the refrigerator, and Cubed for the Ice Type)
23
Operation Function
9-7) Power failure compensating function
l This function is for a display purpose on the floor of show room or store.
1) Mode ON/OFF
1-1) For the exhibition mode, press Power Freeze and Freezer Temp. buttons simultaneously for 5
seconds until a “ding-dong” sounds.
1-2) Press the same time buttons again for 5 seconds to cancel this mode put with a “ding-dong”
sound.
2) Operation
2-1) Most of the system function except the compressor operation are working properly.
2-2) There is no defrost cycle in this mode.
9-8) Exhibition Function
1) Self-Diagnostics in the initial Power ON
1-1)The control board performs a self diagnostics test within 1 second and check out the temperature
sensors abilities.
1-2) If a sensor failure occurs, a corresponding LED segment will blink.
1-3) When a LED segment blinks, only the cancellation function (Press Power Freeze and Power Cool
buttons simultaneously for 8 seconds) is acceptable.
1-4) After a replacement of bad sensor or a cancellation of this function, this self diagnostics will end.
2) Self-Diagnostics in the normal operation
2-1) To select this function, press Power Freeze and Power Cool buttons simultaneously for 5 seconds
with an audible tone.
2-2) In the self diagnostic mode, only corresponding LED segments will be illuminated (see the check
list on)
2-3) After a 30 second illumination of error signal, the system will return to the normal operation.
9-9) Self-Diagnostics function