EasyManua.ls Logo

Samsung RB2155SW - Page 6

Samsung RB2155SW
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ELECTRICAL PART SPECIFICATIONS & STANDARD
6
RSCR 250VAC, 12
4TM437RHBYY-53
130±5
69±9
J531Q33E100M200-2
10±20%
IS3210-SNP6D
IS3208-SNP6H
IS3208-SCH6A
ITEM STANDARD
Min. 12hrs, Max. 22Hrs
Min. 6hrs, Max. 11Hrs
10
±
2min
4hr
±
10min
THERMISTOR (502AT), SPEC:5.0K
AT 77
Freezer
Type
F-Sensor
Type
R-Sensor
ON()
–12.0
0
10
ON()
36
42
48
Temperature Selection
–14
–2
8
Temperature Selection
34
40
46
OFF()
–16.0
–4
6
OFF()
32
38
44
Refrigerator
Defrosting
Sensor
Heater
Fuse
First Defrost Cycle
(Concurrent Defrost of F and R)
Defrost Cycle(FRE)
Defrost Cycle(REF)
Pause Time
Freezer-Sensor
Refrigerator-Sensor
FRE Evap-Sensor
REF Evap-Sensor
Ambient TEMP-Sensor
Defrost Heater(FRE)
Drain Heater(FRE)
Defrost Heater(REF)
Drain Heater(REF)
TemperatureElectrical parts
242W
52W
120W
38W
AC250V 10A 77±5˚C
Thermal-Fuse for preventing
overheating of Freezer Defrost-Heater
Thermal-Fuse for preventing
overheating of Freezer Defrost-Heater
110V-130V/15W
110V-130/30W
Capacitor
Over-Load
Protector
STARTING-
RELAY
MOTOR-FAN
LAMP
RUNNING
MODEL
TEMP. ON
TEMP. OFF
MODEL
OPERATION
FRE.
REF.
CIRCUIT
FRE
(INCANDESCENT)
REF
(INCANDESCENT)

Related product manuals