EasyManua.ls Logo

Samsung RB215B Series - Page 38

Samsung RB215B Series
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
38
Temp Control &Operation Functions
No Description OthersError
1
2
3
4
5
6
7
8
9
10
F-SENSOR ERROR
R-SENSOR ERROR
F-DEFROST SENSOR ERROR
R-DEFROST SENSOR ERROR
ICE MAKER SENSOR ERROR
AMBIENT SENSOR ERROR
F-DEFROST HEATER ERROR
R-DEFROST HEATER ERROR
ICE MAKER FUNCTION ERROR
UART COMMUNICATION
ERROR (PLC)
Fault rated F-SENSOR?
Fault rated R-SENSOR?
Fault rated F-DEFROST SENSOR?
Fault rated R-DEFROST SENSOR?
Fault rated ICE MAKER SENSOR?
Fault rated AMBIENT SENSOR?
Fault rated F-DEFROST?
Fault rated R-DEFROST?
Fault ICE MAKER OPERATION?
Communication error with PLC modem
LED Display
- Self Diagnosis Check List
2) Self-diagnosis with initial power on
2-1) When pressing the Super Freeze button and the Super Cool button simultaneously for 6 sec during
normal operation, the entire temperature setting display will blink for 2 sec at the interval of 0.5 sec and
when pressing the Super Cool button and the Super Cool button si mul taneousl y for 8 sec including 2
sec blinking, self-diagnosis will be selected.
2-2) It goes into the Self Diagnosis function with a “Ding-Dong” sound and it shows error codes on the LED
display.And then,it will be restored to the normal operation.
2-3) During self-diagnosis,button inputs will not be recognized but only the canceling buttons.

Table of Contents

Related product manuals