EasyManua.ls Logo

Samsung RB215B Series - Compressor Operation Troubleshooting

Samsung RB215B Series
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
59
Diagnostics
Check out the COMP with the Forced Operation selected
1. If it does not pass 5 min after a desired Temp reached,COMP does not operate.
2. During Defrost,COMP does not operate.
3. With the disconnected F-Sensor or R-Sensor,COMP does not operate because low
temperature is detected.
Pre-Check
13-3) When COMP does not operate
NO
NO
NO
NO
YES
NO
Run Forced Operation
Is Forced Operation on?
Is the
MICOM #22 output
"HIGH"(5V)?
Is the IC70 #12
"LOW"(0.7V)?
Is COMP RELAY normal?
Is the contact
of CONNECTOR CN70
contact normal
Does
COMP ASS'Y Function
normally?
Start
YES
Soldering checkout/
Change MICOM or PCB
Change or repair IC04/
Change PCB
YES
Check RELAY /
Change PCB
Refer to the list (15-1)
YES
Insert Connector completely /
Check its connection
YES
Change/repair COMP
NO
YES
Check wire assembly/connection

Table of Contents