ELECTRICAL PART SPECIFICATIONS & STANDARD
6
RSCR 250VAC, 12
4TM437RHBYY-53
1305
699
J531Q33E100M200-2
1020%
IS3210-SNP6D
IS3208-SNP6H
IS3208-SCH6A
ITEM STANDARD
Min. 12hrs, Max. 22Hrs
Min. 6hrs, Max. 11Hrs
10
2min
4hr
10min
THERMISTOR (502AT), SPEC:5.0K
Ω
AT 77
Freezer
Type
F-Sensor
Type
R-Sensor
ON()
–12.0
0
10
ON()
36
40
48
Temperature Selection
–14
–2
8
Temperature Selection
34
38
46
OFF()
–16.0
–4
6
OFF()
32
36
44
Refrigerator
Defrosting
Sensor
Heater
Fuse
First Defrost Cycle
(Concurrent Defrost of F and R)
Defrost Cycle(FRE)
Defrost Cycle(REF)
Pause Time
Freezer-Sensor
Refrigerator-Sensor
FRE Evap-Sensor
REF Evap-Sensor
Ambient TEMP-Sensor
Defrost Heater(FRE)
Drain Heater(FRE)
Defrost Heater(REF)
Drain Heater(REF)
Ice-maker Heater
TemperatureElectrical parts
242W
52W
120W
38W
10W
AC250V 10A 775˚C
Thermal-Fuse for preventing
overheating of Freezer Defrost-Heater
Thermal-Fuse for preventing
overheating of Freezer Defrost-Heater
110V-130V/15W
X
2
110V-130V/30W
Capacitor
Over-Load
Protector
STARTING-
RELAY
MOTOR-FAN
LAMP
RUNNING
MODEL
TEMP. ON
TEMP. OFF
MODEL
OPERATION
FRE.
REF.
CIRCUIT
FRE
(INCANDESCENT)
REF
(INCANDESCENT)