Defrost Control ··············From 12 to 22 hrs(comp.run time)
Thermo Bimetal Protector ··········140°F(60℃)(off) 104°F(40℃)(on)
Defrost Thermistor(502AT) ·········· F: 50°F(10℃)(off)
R: 59°F(15℃)(off)
Electrical RatingAC115V 60Hz ···········11.6 Amps
Maximum Current Leakage ··············0.25 mA
Maximum Ground Path Resistance ··········0.1 Ohm
Energy Consumption ··············562kWh/year
Ambient Temperature ········70
℉(21℃) 90℉(32℃)
Refrigerator···············34℉(1℃)∼46℉(7℃)
34℉(1℃)∼46℉(7℃)
Flex Zone················29℉(-1℃)~42℉(5℃)
29℉(-1℃)~42℉(5℃)
Freezer ··············· -8℉(-22℃)∼8℉(-14℃)
-8℉(-22℃)∼8℉(-14℃)
Run Time,%··············60 80
Refrigerant Charge (R134a) ···········5.64 oz(160g)
MKV190C-L2B ·············1314 Btu/hr(0.385kw)
Compressor oil ················· Freol α15c
R Capillary tube(Dia, Length) ··········0.032
""
,118
""((00..8822mmmm,,33550000mmmm))
F Capillary tube(Dia, Length) ··········0.032
""
,118
""((00..8822mmmm,,33550000mmmm))
Clearance must be provided for air circulation
AT TOP ·····················2" (50mm)
AT SIDES ··················· 3¾"(95mm)
AT REAR ···················· 2" (50mm)
ELECTRICAL SPECIFICATIONS REFRIGERATOR
13
2-2) Specifications
PRODUCT SPECIFICATIONS
NO LOAD PERFORMANCE
REFRIGERATION SYSTEM
INSTALLATION
FREEZER
FLEX ZONE
CompressorStep Valve
C-FanDryer
Condenser Water Valve
AW3 SM-EN 2011.3.31 2:52 PM 페 이 지 1 3 i n