99
TROUBLESHOOTING
4-3-3. Location Sensing Resistance Area
1) The circuit makes an AD conversion from MICOM for about 3.3V that divides the Motor Back EMF voltage
(DC300V) by 3 of 300K resistance and 10K resistance.