EasyManua.ls Logo

Samsung RFG297AABP - Page 74

Samsung RFG297AABP
121 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
73
TROUBLESHOOTING
10) If Tank Water Heater has trouble
1) Wire connector
2) Replace Heater
Is MAIN PCB connector
(CN79) inserted correctly?
Is the input voltage of
IC01 MICOM #6 normal?
Start
NO
YES
YES
YES
Bad contact of connector/ insert correctly
NO
1) Recheck the wire
2) Replace PCB MAIN
NO
Normal(recheck)
Measure the resistance
between - after
CN79 connector open 72ohm ± 7%
ERROR Code
Checking method of Tank Water Heater
resistance CN79#6(Pink) #10(White)
** ∞Ω: Open(wire disconnection, heater
disconnection) trouble / 0: Short trouble
Start
YES
YES
YES
Initial
power On
Heater off
Working
heater
3.5V ~
4.8V
MICOM
#6
condition
3.5V ~
4.8V
0V
Is Tank Water Heater
normal?(about72ohm)

Table of Contents

Related product manuals