EasyManua.ls Logo

Samsung RFG298AA - LED Blinking Frequency Depending on Protecting Functions

Samsung RFG298AA
135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
97
TROUBLESHOOTING
4-2-19. LED blinking frequency depending on protecting functions
If Failure Condition is detected during compressor is operating, immediately stop Compressor operating and stand
by 5 minutes. During this 5 minutes, RPM command signal is not available. It means, even if available RPM
command signal is applied to the compressor, it does not work and keep standing by.
Blinking time is 1 second and dwell time is 2 seconds.
LED blinking frequency depending on protecting functions
Protecting Functions LED Blinking Frequency Remarks
Starting Failure
SPM Fault
Detecting Positon Failure
Motor locked
Low Voltage
Over Voltage
ROM
RAM
Stack
Reserved

Table of Contents

Other manuals for Samsung RFG298AA

Related product manuals