Samsung Electronics 9-11
Error Mode Thermal fuse open error in power therminal block
Display
Check Method Scanning the error when thermal fuse in power therminal block is opened
Cause Check the connection of terminal block(Temperature rise by screw loosening)
Sensor SPEC.
9-4-9 Thermal Fuse Open Error in Power Therminal Block
No
No
Is the CN140 Connector of PCB correctly
connected to wire?
Restart after connecting
connector.
Yes
Is the ends of the connector shorted?
Occurring E198.
Check both ends of the connector connected
terminal block.
Replace MAIN PBA.
No