Summary

Safety Precautions

General Safety Information and Warnings

Provides essential safety guidelines and warnings for operating the air conditioner safely.

Installation and Power Supply Safety

Deciding on Where to Install the Air Conditioner

General Installation Location Guidelines

Lists general restrictions and elements to avoid when choosing an installation location.

Outdoor Unit Placement Requirements

Specifies requirements for placing the outdoor unit to ensure proper operation and airflow.

Installation Cautions and Considerations

Highlights important cautions and considerations for installing the air conditioner.

Piping Diameter Specifications for RJ040F2HX**

Piping Length and Height Limits

Piping Diameter Specifications for RJ050F2HX**

Piping Length and Height for RJ050F2HX**

Piping Diameter Specifications for RJ060F3HX**

Piping Length and Height for RJ060F3HX**

Piping Diameter Specifications for RJ070/080F4HX**

Piping Length and Height for RJ070/080F4HX**

Space Requirements for Outdoor Unit

Single Outdoor Unit Installation Clearances

Illustrates required clearances around a single outdoor unit for various installation configurations.

Multiple Outdoor Unit Installation Clearances

Shows required clearances for installing multiple outdoor units.

Additional Multiple Outdoor Unit Clearances

Air Conditioner and Accessories

Outdoor Unit Case Accessories List

Lists accessories included in the outdoor unit case for specific models.

Drain Hose Installation and Drainage Check

Provides instructions for installing the drain hose and ensuring adequate drainage.

Piping Cutting and Extension

Piping Preparation and Flaring Techniques

Details cutting piping, removing burrs, and flaring pipe ends correctly.

Flare Nut Tightening Torque Specifications

Specifies torque values for tightening flare nuts on refrigerant pipes.

Connecting Cables to the Outdoor Unit

Compressed Ring Terminal Selection

Provides specifications for selecting appropriate compressed ring terminals for wiring.

Wiring Diagram for RJ040F2HX**/RJ050F2HX**

Cable Specifications and Connections

Wiring Diagram for RJ060F3HX**

Cable Specs and Connections for RJ060F3HX**

Wiring Diagram for RJ070F4HX**/RJ080F4HX**

Cable Specs and Connections for RJ070/080F4HX**

Transmitter Installation (Optional)

Transmitter Accessories and Mounting

Lists transmitter accessories and provides steps for mounting the unit.

Transmitter PCB and Cable Connections

Details attaching the transmitter PCB and connecting communication and power cables.

Transmitter and Unit PCB Diagrams

Dip Switch Settings for Transmitter/Indoor Units

Checking Correct Earthing

Earthing Electrode Installation and Connection

Guides on selecting, installing, and connecting an earthing electrode for the unit.

Earthing Resistance Testing Procedure

Details checking earthing resistance and adjusting electrode depth if needed.

Fixing the Unit in Position

Outdoor Unit Mounting and Support Requirements

Covers positioning the outdoor unit, using anchor bolts, and installing shield plates.

Wall Mounting Rack Installation Guidelines

Provides guidelines for installing the outdoor unit on a wall rack, including vibration reduction.

Connecting Up and Purging the Circuit

Piping Connection and Vacuum Purging Process

Explains how to connect piping and use a vacuum pump to purge air from the system.

Refrigerant Valve and Nut Handling

Details opening/closing refrigerant valves and tightening nuts for the system.

Vacuum Purging for RJ060F3HX**/RJ070F4HX**/RJ080F4HX**

Adding Refrigerant

Refrigerant Addition Based on Pipe Length

Specifies how to add refrigerant based on total pipe length for different models.

Recharging Refrigerant with Liquid Pipe

Guides on recharging refrigerant using a liquid pipe, including cylinder handling.

Fluorinated Greenhouse Gas Information

Performing Leak Tests

Leak Testing Procedures and Refrigerant Information

Details leak testing methods and information on fluorinated greenhouse gases used.

Pump Down Procedure for Repair/Removal

Pump Down Operation Steps

Explains the procedure to collect system refrigerant before unit repair or removal.

Pipe Installation with Indoor Units

Indoor Unit Piping Order Examples

Shows examples of piping installation orders based on indoor unit capacity.

Setting Indoor Unit Address and Installation Option

Auto Addressing Mode Procedure

Guides on performing auto addressing for indoor units and checking communication status.

Indoor Unit Communication Display Codes

Explains codes displayed on the external unit indicating indoor unit communication status.

Manual Addressing Setup and Prerequisites

Indoor Unit Addressing Sequence

Manual Addressing by Indoor Unit Type

Rotary Switch (SW02) Position for Addressing

Installation Test Mode Procedures

Setting Option (AQV07/09/12/18/24****)

Remote Control Option Setting Mode

Guides on entering and using the remote control for setting operational options.

Option Setting Procedure via Remote

Details steps for selecting and inputting option codes using the remote control.

Procedure for Setting Operational Options

Setting an Indoor Unit Address (MAIN/RMC)

Indoor Unit Address Assignment Steps

Explains how to assign addresses to indoor units using a wireless remote controller.

Address Setting Options and Indications

Details options and indications for setting indoor unit and RMC addresses.

Indoor Unit MAIN ADDRESS Setting Rules

Indoor Unit Installation Option Setup

Ampere Limit Setting & Changing Procedure

Ampere Limit Switch Adjustment Guidelines

Provides warnings and procedures for adjusting the Ampere Limit Switch on the outdoor unit PCB.

Ampere Limit Switch Selection Table

Shows default and selectable ampere limit values based on model and switch settings.

Outdoor Unit PCB Display Key and Functions

Outdoor Unit PCB Display Mode Changes

Troubleshooting

Outdoor Unit PCB Error Codes and Explanations

Lists error codes displayed on the outdoor unit PCB and their explanations.

Troubleshooting Remarks and Recommended Actions

Provides remarks and recommended actions for specific error codes.

Additional Outdoor Unit PCB Error Codes

Troubleshooting Remarks for Additional Errors

Explaining Operations to the Owner

Owner Operation Explanation Points

Outlines key operations to explain to the owner before leaving the installation site.

Pump Down Procedure (When Removing Product)

Pump Down Procedure Steps

Details the step-by-step process for performing pump down when removing the product.