EasyManua.ls Logo

Samsung RS2530B - 6-3) When COMP does not operate

Samsung RS2530B
95 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
54
TROUBLE SHOOTING
MICOM voltage
DOOR OPEN : 5V
DOOR CLOSE : 0V
MICOM voltage
0 󳥥 5V alteration
2) When Refrigerator DAMPER does not operate
Forced Operation/
Temp Increase
Is DAMPER in
operating conditions?
Start
NO
YES
DAMPER is normal
Does DAMPER operates
with DOOR S/W pressed?
YES
NO
Change DOOR S/W
Is DOOR S/W normal?
NO
YES
Check soldering/
Change PCB
Is voltage of MICOM
#50 normal?
NO
YES
Check Connector CN75
again
Is insertion of CN75 of
MAIN PCB normal?
NO
YES
Check soldering/
Change PCB
Are voltage of MICOM
Pin #44,45,46 outputed?
NO
YES
Change DAMPER
Is DAMPER normal?
NO
YES
Check wire assembly and connections between
Dampers

Table of Contents

Related product manuals