TROUBLE SHOOTING
6-7) When Room Lamp does not light up
1.Because Room Lamp is basically controled with Door Switch and PBA -SUB,PBA -MAIN does not control it.
1)When Freezer/Refrigerator Lamps do not light up
Start
NORMAL
Note
DOOR OPEN
Is Door Open?
YES
NO
Replace or troubleshoot
the DOOR S/W
Is DOOR SWITCH
NORMAL?
YES
NO
Replace LAMP
Is Room LAMP(R,F)
NORMAL?
YES
NO
Troubleshoot WIRE -HARNESS
Is the voltage 12V on LAMP
RELAY -Coil of PBA -SUB in CASE
PBA -PANEL when you open
the door?
YES
NO
Replace PBA SUB
Is the LAMP RELAY of
PBA -SUB in CASE PBA- PANEL
On when you open
the door?
YES
NO