TROUBLE SHOOTING
NO
Item
Description How to do Self-Diagnosis
FREEZER
SENSOR
FRIDGE
SENSOR
FREEZER
DEFROST
SENSOR
FRIDGE
DEFROST
SENSOR
AMBIENT
SENSOR
CoolSelect
ZONE
SENSOR
ICE
MAKER
SENSOR
FREEZER
FAN
ERROR
FRIDGE
FAN
ERROR
FREEZER
DEFROST
ERROR
FRIDGE
DEFROST
ERROR
ICE MAKER
ERROR
DAMPER
HEATER
ERROR
COMM
ERROR
CONDENSOR
FAN
ERROR
Connector Slipped-Out or Open-Contact, Wire Cut
or Short-Circuited, Abnormal Sensing Temp
(50 (122 )and over, or -50°C(-58 and lower)
The voltage should be within the range of
4.5V~1.0V between MAIN PCB CN30 #3
and #9.
The voltage should be within the range of
4.5V~1.0V between MAIN PCB CN30 #7
and #9.
The voltage should be within the range of
4.5V~1.0V between MAIN PCB CN30 #4
and #9.
The voltage should be within the range of
4.5V~1.0V between MAIN PCB CN30 #10
and #9.
The voltage should be within the range of
4.5V~1.0V between MAIN PCB CN30 #11
and #12.
The voltage should be within the range of
4.5V~1.0V between MAIN PCB CN51
#13 and #14.
The voltage should be within the range of
4.5V~1.0V between MAIN PCB CN90 #3
and #4.
The voltage should be 7V~12V between
MAIN PCB CN74 GRAY and BLUE.
The voltage should be 7V~12V between
MAIN PCB CN74 GRAY and GREEN.
The voltage should be 7V~12V between
MAIN PCB CN74 GRAY and YELLOW.
Disconnect MAIN PCB CN70 from PCB, and
read the resistance between Orange and Brown
wire terminals (Refer to the Wire Diagram for the
resistance value). 0 Ohm Heater Short
Ohm Wire Cut or Blown Thermistor
Disconnect MAIN PCB CN70 from PCB, and
read the resistance between Orange and White
wire terminals (Refer to the Wire Diagram for
the resistance value). 0 Ohm Heater Short
Ohm Wire Cut or Blown Thermistor
After replacing Ice-Maker, plug in the unit
and check its operation.
Disconnect MAIN PCB CN73 from PCB, and
read the resistance between Black and Brown
wire terminals (Refer to the Wire Diagram for
the resistance value). 0 Ohm
Heater Short
Ohm Wire Cut or Slipped-out Terminal
It needs a Oscilloscope to do the error check.
So, it is more realistic checking the error after
replacing Main or Panel PCB.
Same as the above
Same as the above
Same as the above
Same as the above
Same as the above
Same as the above
Same as the above
Same as the above
Bad Feed-Back Signaling Wire
Contact, Motor Wire Slipped-Out,
Defective Motor
Connector Slipped-Out or Open-
Contact, Wire Cut or Short-Circuited,
Defective Thermistor, or When it keeps
heating during Fridge Defrost even
after it does defrosting for 80 minutes.
Connector Slipped-Out or Open-
Contact, Wire Cut or Short-Circuited,
Defective Thermistor, or When it keeps
heating during Fridge Defrost even
after it does defrosting for 80 minutes.
I/M Ice Ejection Horizontal Positioning
Error ** Only for Dispenser models
Damper Heater is sensed as open
error due to Connector Slipped-Out or
Open-Contact, Wire Cut.
No communication between MICOM
MAIN and PANEL => The PC E error
code will light up with alarming sounds.
Descriptions of Self-Diagnosis Error Code
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
54