EasyManua.ls Logo

Samsung RXS18YBT User Manual

Samsung RXS18YBT
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
RAC for North America
(INV, R410A, 60Hz, HP)
RAC
Technical
Data Book
Model : AR**TSF*BWKNCV (Indoor Unit)
AR**TSF**WKXCV (Outdoor Unit)
Question and Answer IconNeed help?

Do you have a question about the Samsung RXS18YBT and is the answer not in the manual?

Samsung RXS18YBT Specifications

General IconGeneral
BrandSamsung
ModelRXS18YBT
CategoryAir Conditioner
LanguageEnglish

Summary

History

Nomenclature

Line-up Indoor Unit

Line-up Outdoor Unit

1. Specification

Quantum 2.0 Specifications

Detailed technical specifications for Quantum 2.0 models, including performance and system data.

2. Capacity Table

Quantum 2.0 Capacity Tables

Cooling and heating capacity tables for Quantum 2.0 models under various conditions.

Wind-Free 2.0 Capacity Tables

Cooling and heating capacity tables for Wind-Free 2.0 models under various conditions.

Max Heat 2.0 Capacity Tables

Cooling and heating capacity tables for Max Heat 2.0 models under various conditions.

3. Dimensional Drawing

Indoor Unit Dimensions

Dimensional drawings and measurements for indoor units of various models.

Outdoor Unit Dimensions

Dimensional drawings and measurements for outdoor units of various models.

4. Center of Gravity

Indoor Unit Center of Gravity

Center of gravity points for indoor units, indicating balance and mounting considerations.

Outdoor Unit Center of Gravity

Center of gravity points for outdoor units, crucial for secure installation.

5. Electrical Wiring Diagram

Indoor Unit Wiring

Detailed electrical wiring diagram for indoor units, showing component connections.

Outdoor Unit Wiring

Detailed electrical wiring diagram for outdoor units, outlining component connections.

6. Sound Data

Indoor Unit Sound Levels (Quantum 2.0)

Sound pressure level data and NC curves for Quantum 2.0 indoor units.

Indoor Unit Sound Levels (Max Heat/Wind-Free)

Sound levels and NC curves for Max Heat 2.0 and Wind-Free 2.0 indoor units.

Outdoor Unit Sound Levels (Quantum 2.0)

Sound pressure level data and NC curves for Quantum 2.0 outdoor units.

Outdoor Unit Sound Levels (Wind-Free 2.0)

Sound pressure levels and NC curves for Wind-Free 2.0 outdoor units.

Outdoor Unit Sound Levels (Max Heat 2.0)

Sound pressure levels and NC curves for Max Heat 2.0 outdoor units.

7. Temperature and air flow distribution

Quantum 2.0 Airflow and Temp. Distribution

Air velocity and temperature distribution charts for Quantum 2.0 models.

Max Heat/Wind-Free Airflow and Temp. Distribution

Distribution charts for Max Heat 2.0 and Wind-Free 2.0 models.

8. Piping Diagram

9. Operation Limit

Quantum 2.0 & Wind-Free 2.0 Operation Limits

Graphical representation of operating limits for Quantum 2.0 and Wind-Free 2.0 models.

10. Capacity Correction

Outdoor Unit Capacity Correction

Capacity correction factors for outdoor units based on pipe length and level difference.

11. Installation

Typical Installation Overview

General guidance on typical installation procedures for the air conditioning unit.

Indoor Unit Installation Location

Requirements and considerations for selecting an indoor unit installation site.

Outdoor Unit Installation Location

Requirements and considerations for selecting an outdoor unit installation site.

Indoor Unit Mounting and Wiring

Steps for attaching the mounting bracket and connecting electrical cables.

Outdoor Unit Mounting

Instructions for mounting the outdoor unit on the ground or on a wall.