Samsung SGH-E770 - DCS Receive Path Diagnostics

Samsung SGH-E770
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SAMSUNG Proprietary-Contents may change without notice
SGH-E770 Flow Chart of Troubleshooting
2-18
This Document can not be used without Samsung's authorization
2-2-2. DCS RX
Continuous RX ON
RF Input : 660 CH
AMP : -50dBm
NORMAL CONDITION
Catch the channel ?
YES
NO
F100 Check
Pin #6
-65dBm ?
F100 Check
Pin #13
-65dBm ?
UCD100 Check
Pin#43
-65dBm ?
Check soldered status of
R125, 11, C12, 153, L108, 106
PAM101, C10
Resolder or Change
F100 Resolder or Change
UCD100 Check
Pin#15,16,23,27,31
=Clean 2.8V?
UCD100 Check
Pin#28,29,30,54=100mV?
C17, 18, 114, 152, UCP301
Check or resolder
Check UCP301
NO
NO
YES
YES
YES
YES
NO
YES
UCD100 Check
Pin #17 : 13MHz ?
Vpp : 1.1V?
R118 = 13MHz ?
Vpp : 1.2V?
R116 = 1.5V ?
UCD100
Change or resolder
NO
NO
NO
C141, R118
resolder
TCX101
Change or resolder
YES
YES YES
NO
Check soldered status of
L104, C123
NO