EasyManua.ls Logo

Samsung SR-L628EV - Page 13

Samsung SR-L628EV
59 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Samsung Electronics 15
No
1
2
3
4
5
6
7
Symptom
• R-room left sensor housing
disconnection.
• Faulty connection.
• Wire open or short.
• Faulty sensor.
• R-room left right sensor
housing disconnection.
• Faulty connection.
• Wire open or short.
• Faulty sensor.
• R-room defrost sensor
housing disconnection.
• Faulty connection.
• Wire open or short.
• Faulty sensor.
• Outer sensor housing
disconnection.
• Faulty connection.
• Wire open or short.
• Faulty sensor.
• F-room sensor housing
disconnection.
• Faulty connection
• Wire open or short.
• Faulty sensor.
• R-room defrost sensor
housing disconnection.
• Faulty connection.
• Wire open or short.
• Faulty sensor.
• Faulty geared-motor
• Faulty reed-switch
housing disconnection.
• Faulty connection.
Remark
R1-Sensor temperature is
over +50˚C or below –50˚C.
R2-Sensor temperature is
over +50˚C or below –50˚C.
RD-Sensor temperature is
over +50˚C or below –50˚C.
Outer-Sensor temperature
is over +50˚C or below
–50˚C.
F-Sensor temperature is
over +50˚C or below –50˚C.
F-Sensor temperature is
over +50˚C or below –50˚C.
Square wave not detected
by reed-S/W.
Item
R1-Sensor
R2-Sensor
RD-Sensor
Air-Sensor
F-Sensor
FD-Sensor
Geared-
Motor
Display LED
Refrigerator “LOW”
Refrigerator
“LOW · Med”
Refrigerator “Med”
Freezer “LOW”
Freezer “L O W ” · Med”
Freezer “Med”
Refrigerator “HIGH”
(Self-diagnosis Display Table)

Table of Contents

Related product manuals