EasyManua.ls Logo

Samsung SR-S24FTA - 7-7. Self-Diagnosis Function

Samsung SR-S24FTA
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7-7.
Self-Diagnosis
Function
)
1.
Self-Diagnosis
Function
on
the
first
POWER-ON
1)
On
the
first
Power-on,
lamps
are
ALL
ON
and
self-diagnosis
function
operates
internally.
"
9)
If
there
is
no
fault
on
the
self-diagnosis,
DISPLAY
will
show
the
first
normal
state.
3)
If
there
is
any
fault
on
the
self-diagnosis,
the
relevant
LED
will
flicker
and
alarm
will
sound.
4)
ERROR
(indicating
fault)
display
by
the
self-diagnosis
will
continue
till
all
the
relevant
problems
is
fixed
or
the
self-diagnosis
is
canceled.
5)
When
the
relevant
problems
is
solved,
DISPLAY
will
return
to
the
normal
MODE.
6)
After
fixation
of
refrigerator,
power
should
be
off
and
on
a
gain
to
check
whether
the
fault
is
corrected.
7)
So,
if
there
is
a
need
to
check
SENSOR
OPEN
&
SHORT
for
A/S,
sensor
can
be
checked
through
the
self-
diagnosis
operation
by
power-off
and
on.
8)
If
there
is
any
problem,
the
relevant
DISPLAY
is
as
follows.
_T
tur
i
icemaker
|
Temperature
setting
in
|
OPEN
and
SHORT
type
problem
with
ae
sk
oy
-
o1
the
refrigerator
_
sensor
located
at
the
bottom
of
ice
tray
-
j
SENSOR
-
ne
;
below
-
50°C
on
the
model
“WARMER’
(Ist
step)
problem
with
wire
connection
.
with
Ice-Maker
ing
i
Problem
di
Temperature
setting
in
|
Fach
of
Reroom
sensor
housing,
em
display
nen
R-Room
the
refrigerator
:
:
temperature
by
R-sensor
is
above
02
contact
problem,
wire-snapping,
Short,
;
R-Sensor
|“WARMER-MEDIUM”
+50°C
and
below
-
50°C
R-Sensor
fault
and
so
on.
:
(2nd
step)
on
the
model
with
Ice-Maker
Problem
displ
Temperature
setting
in]
|
Detach
of
R-room
sensor
housing,
robe
ciep
ey
ie
;
R-Room
:
;
;
temperature
by
R
defrost-sensor
is
03
Reha
eexeo
the
refrigerator
contact
problem,
wire-snapping,
Short,
above
+50°C
and
below
-50'C
a
e
-
“MEDIUM”
(3rd
step)
R-Sensor
fault
and
so
on.
oo
iid
Re
the
model
with
Ice-Maker
Wh
al
ion
d
Temperature
setting
in
Problem
with
MICRO
S/W,
Motor,
a
mer
sea
ne
ICE-MAKER
:
as
we
return
in
spite
of
3
Eject
operation
04
the
refrigerator
Gear,
and
other
wiring
system
inside
iesenndet
KIT
on
the
mode
“COLDER”
(4rd
step)
Gear
Bo
:
L
P
oe
with
Ice-Maker
ay
eee
ee
Detach
of
Ambient-Sensor
housing
Problem
display
when
05
Ambient
:
ieee
2
inside
PCB
Base
at
the
top
of
the
temperature
by
Ambient-sensor
Sensor
refrigerator,
Contact
problem,
Wire-
is
above
+
50°C
and
below
-
50°C
“WARMER”
(Ist
step)
:
ie
53
Snapping,
Short,
Sensor
fault
and
soon
|
on
the
model
with
icemaker
[
:
|
Temperature
setting
in
|
Detach
of
F-Room
Sensor
housing
inside
Problem
display
when
06
F-Room
the
freezer
PCB
Base
at
the
top
of
the
refrigerator,
|
temperature
by
F-sensor
is
above
ESensor
|“WARMER-MEDIUM”}
Contact
problem,
Wire-Snapping,
+50°C
and
below
-
50°C
on
the
(2nd
step)
Short,
Sensor
fault
and
so
on
model
with
icemaker
i.
|
a
Detach
of
Defrost-Sensor
housing
Problem
display
when
Temperature
setting
in
eh
a
F-Room
ae
inside
the
evaporator
of
F-Room,
temperature
by
F
Defrost-sensor
Defrost
Sensor
=
Contact
problem,
Wire-Snapping,
[is
above
+
50°C
and
below
-
50°Co
“MEDIUM”
Grd
step)
;
Short,
Sensor
fault
and
so
on
the
model
with
fce-Maker
Note
:
This
self-diagnosis
operates
when
there
is
OPEN
and
SHORT
type
problem
with
Sensors.
If
the
changes
in
Sensor
are
within
the
ranges
of
the
temperature
described
in
the
remarks,
they
are
not
judged
to
be
fault
and
the
appliance
operates
normally.

Other manuals for Samsung SR-S24FTA

Related product manuals