23 Samsung Electronics
8-8. Division of OPTION
The output such as GRID wave form which is only generated at the initial POWER ON is accepted as
input through SWITCHING DIODE and discriminate OPTION by matrix method. #23, #24, and #25 PORT
of MICOM PORT generate the same output with GRID wave form only at initial POWER ON.
Shift of temperature in freezer compartment(unit :
˚C)
SHIFT
Default
-1.0˚C
-2.0˚C
-3.0˚C
+1.0˚C
+2.0˚C
+3.0˚C
+4.0
˚C
3
0
0
0
0
1
1
1
1
2
0
0
1
1
0
0
1
1
1
0
1
0
1
0
1
0
1
Shift of temperature in refrigerator compartment
(unit :
˚C)
SHIFT
Default
-1.0˚C
-2.0˚C
-3.0˚C
+1.0˚C
+2.0˚C
+3.0˚C
+4.0
˚C
6
0
0
0
0
1
1
1
1
5
0
0
1
1
0
0
1
1
4
0
1
0
1
0
1
0
1