4-2. How to Check Fault Symptom
Diagnostics
Power cord on.
Yes
Check ‘Stand-By A13V’
13V appear at BD210?
0V to A13V (CN202 #3)
No
Cause : There did not supply the
power from SMPS.
Measure : Change 10p power cable or
SMPS.
Yes
Set On.
Yes
Check ‘SW_POWER’
more than B3.3V appear at CN202(#6)
0V to B3.3V↑ (CN202 #6)
No
Cause : Main IC(NT16L) did not
control the SW_Power.
Measure : Change the Main Assy.
Yes
Check ‘Power of main IC(B1.15V)’ appear
at BD917
Check ‘Power of DDR IC(B1.5V)’ appear
at BD911
No
Cause : There is problem at
DCDC(IC201)/LDO(IC204).
Measure : Change the Main Assy.
Yes
Check ‘Power of LVDS (13V)’
appear at PANEL_VCC?
0V to 13V (TP-PANEL_VCC)
No
Cause : TThere is proble at
FET(Q202_NFRC) or d Main
IC(NT16L) did not control the
SW_PVCC.
Measure : Change the Main Assy.
Yes
Change the LVDS cable.
No
Change the Panel.
4-2
4. Troubleshooting