4-5.White Balance - Calibration
White Balance Manual adjustment
DEVICES PANEL-TYPE
CA-210
40D6AF0S
RGB Measurement
Levels
Code Check
10 IRE 0x01 O
20 IRE 0x02 O
30 IRE 0x03 X
40 IRE 0x04 O
50 IRE 0x05 X
60 IRE 0x06 X
70 IRE 0x07 O
80 IRE 0x08 X
90 IRE 0x09 X
100 IRE 0x0A O
Panel Inspection Spec.
Levels
Check x(±) y(±) Gamma(±)
10 IRE O 0.02 0.02 0.4
20 IRE O 0.02 0.02 0.4
30 IRE O 0.02 0.02 0.4
40 IRE O 0.02 0.02 0.4
50 IRE O 0.02 0.02 0.4
60 IRE O 0.02 0.02 NA
70 IRE O 0.02 0.02 NA
80 IRE O 0.02 0.02 NA
90 IRE O 0.02 0.02 NA
100 IRE O NA NA NA
Gray Check Adjust Spec(xyL) Adjust Target offset(xyL)
Levels
Code Check x(±) y(±) L(±) x(±) y(±) L(±)
10 IRE 0x01 X 0.005 0.005 0.07 0 0 0
20 IRE 0x02 O 0.005 0.005 0.05 0 0 0
30 IRE 0x03 X 0.005 0.005 0.04 0 0 0
40 IRE 0x04 O 0.004 0.004 0.03 0 0 0
50 IRE 0x05 X 0.004 0.004 0.02 0 0 0
60 IRE 0x06 X 0.004 0.004 0.02 0 0 0
70 IRE 0x07 O 0.004 0.004 0.02 0 0 0
80 IRE 0x08 X 0.004 0.004 0.01 0 0 0
90 IRE 0x09 X 0.004 0.004 0.01 0 0 0
100 IRE 0x0A X NA NA NA NA NA NA
4-25
4. Troubleshooting