4-2-4. Jog Function Control
Jog Function Control Operation
Press Left Right Up Down
Major check points
Check Jog Shuttle STBY Voltages (All at 1. 3.3 V except LED).
Check Jog Shuttle 5 SW Operation (Key 1 & Key 2) for each command change.2.
Check LED Indicator for STBY operation. (Check 3. 1.8 V Supply from Main Board.)
Pin Action Signal DC Voltage
1 IR Gnd No connection
2 LED 1.8V ( in STBY)
3 left Key 2 3.3V DC to 1.6V DC
3 Right Key 2 3.3V DC to 2.5V DC
3 Up Key 2 3.3V DC to 0.0V DC
3 Down Key 2 3.3V DC to 0.8V DC
4 Press Key 1 3.3V DC to 0.0V DC
5 SDA 3.3V
6 SCL 3.3V
7 STBY 3.3V
8 GND
9 IR IR 3.3V to 2.5V DC
With Commands