3-2-4 LED display indication in case of error detection
Samsung Electronics 3-3
3-2-5 Panel key operation
Key operational function Key Type
Operation/Stop • Start and stop of operation
- Once ON=start of operation, again ON=stop of operation TACT
- No operation continuously.
Function selection • Change of the operation mode(in case of the model option cooling only)
- It is selected with "COOL → FAN"(default=COOL) for each once turn on. TACT
- In case that the operation off, it is treated invalidity.
- No operation continuously.
Flow wind selection • Set the fan motor speed
- It is selected with
"HIGH → MED → LOW → HIGH" for each once turn on. TACT
- In case that the operation off, it is treated invalidity.
- No operation continuously.
Temperature • It is increased the desired temperature that displayed now.
adjustment - The desired temperature is increased for each pressing with 1°… unit.
(increase) (Increase:18˚C → 19˚C → .. → 21˚C → .. → 23˚C → .. → 29˚C → 30˚C
64˚F → 65˚F → .. → 70˚F → .. → 80˚F → .. → 85˚F → 86˚F)
- In case that the desired temperature is 30˚C, 86˚F…, if the
"increase key is pressed, it is not increased. TACT
If you press the "Increase/Decrease" key of the remote controller,
it occurs the alarm horn at above status.
- It is possible a single shot and continue operation.
- In case of the operation off and flow wind operation, it is treated invalidity.
Temperature • It is decreased the desired temperature that displayed now.
adjustment - The desired temperature is decreased for each pressing with 1˚... unit.
(decrease) (Decrease:30˚C → 29˚C → .. → 23˚C → .. → 21˚C → .. → 19˚C → 18˚C
86˚F → 85˚F → .. → 80˚F → .. → 70˚F → .. → 65˚F → 64˚F)
- In case that the desired temperature is 18˚C, 64˚F…, if the
"decrease key is pressed, it is not decreased. TACT
If you press the "Increase/Decrease" key of the remote controller, it occurs the alarm
horn at above status.
- t is possible a single shot and continue operation.
- In case of the operation off and flow wind operation, it is treated invalidity.
Key description
Key name
Installation and Operating Instructions
1. Set operation in case of error occurrence.
• Malfunction of each temperature sensor (open, short)
- Error mode display, warning sound.
- The operation status is off.
ERROR OPERATION
ROOM THERMISTOR
(OPEN OR SHORT)
7-SEG
LED DISPLAY(LE01)
E1 displayed
AW0690-00162A-1 5/16/00 11:33 AM Page 3-3