3-5
3. PRODUCT SPECIFICATIONS
3-3. NEW FEATURES
1. Auto power S/W off function
After selecting the function, the auto power S/W off function automatically switches power off for you if you do not press
start/pause button for 10 minutes.
Until 5 minutes past, After fi nishing the last function, the auto power S/W off function automatically switches power off for
you if you do not re-select the course button or manual button.
2. Door open function
Door just can be opened at water level 23.5 KHz over, water temperature 55˚C below.
If door is open during the operating, all operating is halted, and door error message will be displayed (2-digit panel
displays “dE” 4-digit panel displays “door”) and error melody will coming out.
Door open error can be cleared by closing the door. the operating keeps going on.
3. Rinse hold function
If rinse hold function selected, the operating is fi nished , the machine do not drain the water after last rinse
4. No spin function
If no spin function selected, the operating is fi nished after last rinse.
5. Drain function
Drain function is over, after pumping out the water for 2 minutes , without motor rotating.
6. Laundry Level function
Laundry Level function can be selected, when you choice the Cotton, Economy, Quick, Baby Cotton, Intensive Delicate,
Hand Wash, Calm Wash, Anti-Allergic rinse, Prewash+
Water level/reverse time is the same with the selected course.
Cycle time is changed by selected laundry level.
7. Rinse times function
Rinse times can be changed. Maximum number of rinse cycles is different by the course.
8. Power-out compensation function
If power is out on selected process, the process before power out is stored to EEPROM, once power is back the process
before power out continues.
When power is back, washing process starts from the process at the point of the power out, rinse/drain process starts from
the initial process.
POWER-OUT COMPENSATION FUNCTION PROCESS
y
y
y
y
y
y
y
y
y
y
y
y
y
y
START WASHING
RINSE/DRAIN
START
RINSE/DRAIN
PROCESS
FINISH
SAVE DATA to
EEPROM
POWER OUT
POWER BACK
MICOM
RESTORE
SAVE DATA to
EEPROM
POWER OUT
POWER BACK
MICOM
RESTORE
RESTART
PROCESS
READ DATA
(PROCESS+TIME)