Removal and Reassembly _ 17
Part Figure Description
DRAIN PUMP
(Continued)
4. Removethe2screwsholdingtheDrainPump.
5. Draintheremainingwaterthroughthedrainage
hose.
6. Disconnectthewireconnector.
7. Pushitbackandliftitup.
* CheckPointsforTroubleshooting
1. SeparatetheDrainFilterandcheckforanyaliensubstancesinsidethepump(e.g.coins,
buttons..,etc.)→Removeiffound.
2. CheckthewireconnectorfortheDrainPumpASSYhasn’tcomeloose.Reconnectif
necessary.
3. Whenwaterleaks,checktheassemblystatusoftheClampHose,andCapDrain→Take
therelevantcountermeasureifnecessary.
Turntheltercapcounterclockwise,cleanandremoveanymaterialthathascollected.