Troubleshooting _ 25
Error Type
Error Mode
Causes Corrective Actions Description of Photo
LED LCD
WaterSupply
Error
nF
nF1
• Watersupplyvaluefault
• MainPCBfault
• Freezinginthewinter
season
• Ifthewatersupplyvalvehasawire
disconnected,replaceit.
• Checkwhetherthewatersupplyvalve
iscloggedwithforeignmaterialand
whetherwaterissuppliedcontinually.
• Checkwhethernowaterissupplied
becauseoffreezinginthewinter
season.
• IfthePBArelayoperatesabnormally,
replacethePBA.
1. Checktheresistanceforthe
watersupplyvalve.
- Resistance:0.8kto1.8kΩ
betweentheterminalsofthe
watersupplyvalve.
2. Checkwhetherthereis
foreignmaterialinthewater
supplyvalvediaphragm.
3. Ifthewatersupplyvalvelter
isclogged,cleanlter.
DrainError nd
• Drainpumpfault
• Freezinginthewinter
season
• Foreignmaterialsinthe
drainpump
• MainPCBfault
• Checkwhethertherevolutionsofthe
drainpumpmotorarerestrainedby
foreignmaterial.
• Checkthesamethingforthenatural
drainprocess.
• CheckthewireconnectorsonMain
PCBandDrainPumpASSY.The
connectororwiremayhavepoor
physicalconnection.
• Ifthedrainpumpoperatesabnormally
intermittentlywhenthetemperatureof
thewaterinthetubishigh.
• Ifthemotorrevolutionsarerestrained
duetofreezinginthewinterseason,
checkthemethodtoremovethe
freezingandremoveasdirected.
► DRAINMOTOR
Resistance:Approximately
6.3ΩbetweentheTerminals
fortheWaterSupplyValve
[Drain]
[Bubble]
► Checkthedrainpumpresistance.
-Drain:
Resistance:13.5Ω~16.5Ω
-Bubble:
Resistance:18.75Ω~22.75Ω

Related product manuals