Troubleshooting _ 43
Error Type Error Mode Causes Corrective Actions Description of Photo
Temperature
SensorError
tE1
tE2
tE3
• Washingtemperaturesensorfault
• Drytemperaturesensorfault
• Faultyandincorrectconnections
ofthedrycondensingsensor
• MainPCBfault
• Freezinginthewinterseason
• Checktheconnectionsforthewashingheater
temperaturesensorconnector.
• Ifthewashingheatertemperaturesensorhas
afunctionalerror,replaceit.
- AtE1erroroccurs.
• Checktheconnectionsforthedryheater
temperaturesensorconnector.
• Ifthedryheatertemperaturesensorhasa
functionalerror,replaceit.
- AtE2erroroccurs.
• Checktheconnectionsfortheduct
condensingtemperaturesensorconnector.
• Iftheductcondensingtemperaturesensor
hasafunctionalerror,replaceit.
- AtE3erroroccurs.
-
UnbalanceError UE
• Motorhallsensorfault
• Causedbythelaundry
• Checkthetypeoflaundry.Checkwhether
theymaycauseanunbalancedsituation.
- Iftheyaresmallbutabsorbalotofwater,
makesuretocheckandfollowtherelated
directionsintheusermanualandfollow
thedirections.
-