1th Edition of TEMP2000_Series IM : Dec. 15. 2008 Page 37 / 63
7.11 PID Group
This setting parameter D-register group is used to establish 6 PID GROUP
PID setting D-Register
D-Reg. Symbol Descriptions
D1001 RP1
D1002 RP2
D1003 RP3
D1004 RP4
Reference Point 1 (T1) to define PID ZONE.
D1009 RHYS Selects hysteresis when ZONE PID.
D1010 RDEV Sets deviation for selecting deviation PID.
D1013 CMOD Select the control method. (0:D.PV, 1:D.DV)
D1015 AT.POINT Auto-tuning sets the reference value.
D1017 AT.DISPLAY Setting to display or hide AT KEY. (0:HIDE, 1:DISPLAY)
D1019 PID.OPMODE Select sets of PID. (0:SEG, 1:ZONE)
D1021 PID.APP ZONE PID sets of selection criteria. (0:PV, 1:SP)
D1101 1_P Proportional band of PID1
D1102 1_I Integral time of PID1
D1103 1_D Differential time of PID1
D1104 1_OH Control Output High limit of PID1
D1105 1_OL Control Output Low limit of PID1
D1106 1_MR Integral time of PID1 is set manually.
D1107 1_HHYS PID1 the ON / OFF control hysteresis High limit is set at.
D1108 1_LHYS PID1 the ON / OFF control hysteresis at the Low setting.
.
.
.
.
.
.
.
.
.
D1141 6_P Proportional band of PID6
D1142 6_I Integral time of PID6
D1143 6_D Differential time of PID6
D1144 6_OH Control Output High limit of PID6
D1145 6_OL Control Output Low limit of PID6
D1146 6_MR Integral time of PID6 is set manually.
D1147 6_HHYS PID6 the ON / OFF control hysteresis High limit is set at.
D1148 6_LHYS PID6 the ON / OFF control hysteresis at the Low setting.